POMCube Inc. |
PNZ-10K1N2-NA0 [240V] |
Inverter |
N/A |
10 kW Hybrid Inverter with PCS functionality |
Qcells North America |
Q.TRON BLK M-G2+/AC 405 |
ACPV |
Q.HOME COMBINER 80 G1, Consumption CT: XH-SCT-S24-200A, Production CT: CT-HQ-SOLID-200A |
349 W, 405 Wdc, AC PV module with integrated microinverter Q.MI.349G-B1. PCS functionality, PEL, backfeed power limit. |
Qcells North America |
Q.TRON BLK M-G2+/AC 410 |
ACPV |
Q.HOME COMBINER 80 G1, Consumption CT: XH-SCT-S24-200A, Production CT: CT-HQ-SOLID-200A |
349 W, 410 Wdc, AC PV module with integrated microinverter Q.MI.349G-B1. PCS functionality, PEL, backfeed power limit. |
Qcells North America |
Q.MI.349B-G1 [240V] |
PV Inverter |
Q.HOME COMBINER 80 G1, Consumption CT: XH-SCT-S24-200A, Production CT: CT-HQ-SOLID-200A |
349 Wac integrated microinverter of the Qcells AC PV modules Q.TRON BLK M-G2+/AC xxx, where xxx = 405, 410. PCS functionality: PEL and backfeed power limit. |
SunPower |
SV-BASE13-12-A |
ESS |
Import Only Mode: Hub+ (SV-HUB-01-C or SV-HUB-01-B)
Export Only Mode: Hub+ (SV-HUB-01-C or SV-HUB-01-B) and ABB Relay AF26-30-0013/AF30-30-00-13 (for projects with non-backup solar circuits) |
Energy Storage System paired with a SunPower Hub+ Panelboard (SV-HUB-01-C or SV-HUB-01-B) for PCS functionality. |
SunPower |
SV-BASE13-12-B |
ESS |
Import Only Mode: Hub+ (SV-HUB-01-C or SV-HUB-01-B)
Export Only Mode: Hub+ (SV-HUB-01-C or SV-HUB-01-B) and ABB Relay AF26-30-0013/AF30-30-00-13 (for projects with non-backup solar circuits) |
Energy Storage System paired with a SunPower Hub+ Panelboard (SV-HUB-01-C or SV-HUB-01-B) for PCS functionality. |
SunPower |
SV-BASE13-C |
ESS |
Import Only Mode: Hub+ (SV-HUB-01-C or SV-HUB-01-B)
Export Only Mode: Hub+ (SV-HUB-01-C or SV-HUB-01-B) and ABB Relay AF26-30-0013/AF30-30-00-13 (for projects with non-backup solar circuits) |
Energy Storage System paired with a SunPower Hub+ Panelboard (SV-HUB-01-C or SV-HUB-01-B) for PCS functionality. |
SunPower |
SV-BASE19.5-C |
ESS |
Import Only Mode: Hub+ (SV-HUB-01-C or SV-HUB-01-B)
Export Only Mode: Hub+ (SV-HUB-01-C or SV-HUB-01-B) and ABB Relay AF26-30-0013/AF30-30-00-13 (for projects with non-backup solar circuits) |
Energy Storage System paired with a SunPower Hub+ Panelboard (SV-HUB-01-C or SV-HUB-01-B) for PCS functionality. |
Anker Innovations Limited |
X1-P6K-B05-US |
ESS |
Backup Controller 200-H and Current Transformers XH-SCT-S24 |
Energy Storage System paired with Backup Controller 200-H for PCS functionality. |
Anker Innovations Limited |
X1-P6K-B10-US |
ESS |
Backup Controller 200-H and Current Transformers XH-SCT-S24 |
Energy Storage System paired with Backup Controller 200-H for PCS functionality. |
Anker Innovations Limited |
X1-P6K-B15-US |
ESS |
Backup Controller 200-H and Current Transformers XH-SCT-S24 |
Energy Storage System paired with Backup Controller 200-H for PCS functionality. |
Anker Innovations Limited |
X1-P6K-B20-US |
ESS |
Backup Controller 200-H and Current Transformers XH-SCT-S24 |
Energy Storage System paired with Backup Controller 200-H for PCS functionality. |
Anker Innovations Limited |
X1-P6K-B25-US |
ESS |
Backup Controller 200-H and Current Transformers XH-SCT-S24 |
Energy Storage System paired with Backup Controller 200-H for PCS functionality. |
Anker Innovations Limited |
X1-P6K-B30-US |
ESS |
Backup Controller 200-H and Current Transformers XH-SCT-S24 |
Energy Storage System paired with Backup Controller 200-H for PCS functionality. |
Tesla Inc. |
1850000-XX-Y |
ESS |
Tesla Gateway 2 (1232100-xx-y) or Tesla Backup Switch (1624171-xx-y) plus Backup Gateway 3 (1841000-xx-y) |
Energy Storage System paired with either Tesla Gateway 2 or Tesla Backup Switch plus Backup Gateway 3 for PCS functionality. |
Enphase Energy Inc. |
ENCHARGE-10-1P-NA |
ESS |
Enphase IQ Combiner or Envoy, Enphase CT-200-SPLIT
Backup Enabled: Enphase Enpower |
Energy Storage System paired with Enphase IQ Combiner or Envoy for PCS functionality. May be paired with PV system, resulting in an increased maximum open loop response time of 9 seconds. |
Enphase Energy Inc. |
ENCHARGE-3-1P-NA |
ESS |
Enphase IQ Combiner or Envoy, Enphase CT-200-SPLIT
Backup Enabled: Enphase Enpower |
Energy Storage System paired with Enphase IQ Combiner or Envoy for PCS functionality. May be paired with PV system, resulting in an increased maximum open loop response time of 9 seconds. |
Enphase Energy Inc. |
IQBATTERY-5P-1P-NA [240V] |
ESS |
For Import Only Mode: Enphase IQ Gateway, at least one CT-200-SPLIT or CT-200-CLAMP for ESS, at least two CT-200-SPLIT or CT-200-CLAMP for consumption, at least one CT-200-SOLID for PV, Enphase IQ System Controller 3/3G (optional)
For Export Only Mode: Enphase IQ Gateway, at least one CT-200-SPLIT or CT-200-CLAMP for ESS, at least two CT-200-SPLIT or CT-200-CLAMP for consumption, at least one CT-200-SOLID for PV, Enphase IQ System Controller 3/3G (optional), Enphase IQ System Controller 2 (optional) |
Energy Storage System paired with Enphase IQ Gateway for PCS functionality. May be paired with PV system, and/or Enphase IQ System Controller. |
Enphase Energy Inc. |
IQBATTERY-5P-1P-NA [208V] |
ESS |
Enphase IQ Gateway, at least one CT-200-SPLIT or CT-200-CLAMP for ESS, at least two CT-200-SPLIT or CT-200-CLAMP for consumption, at least one CT-200-SOLID for PV. |
Energy Storage System paired with Enphase IQ Gateway for PCS functionality. May be paired with PV system. |
Tesla Inc. |
1707000-XX-Y |
ESS |
Backup Gateway 2 (1232100-XX-Y), or Backup Switch (1624171-XX-Y), or Backup Gateway 3 (1841000-XX-Y) |
Energy Storage System paired with Tesla Gateway 2 or Backup Switch or Tesla Gateway 3 for PCS functionality, may be paired with PV system. |
Tesla Inc. |
AC Powerwall 1092170-xx-y |
ESS |
Tesla Gateway 1 (1118431-xx-y) or Tesla Gateway 2 (1232100-xx-y) |
Energy Storage System paired with Tesla Gateway for PCS functionality |
Tesla Inc. |
AC Powerwall 2012170-xx-y |
ESS |
For Import Only Mode: Tesla Gateway 1 (1118431-xx-y) or Tesla Gateway 2 (1232100-xx-y)
For Export Only Mode: Tesla Gateway 2 (1232100-xx-y) |
Energy Storage System paired with Tesla Gateway for PCS functionality. May be paired with PV system. |
Tesla Inc. |
AC Powerwall 3012170-xx-y |
ESS |
Tesla Gateway 2 (1232100-xx-y) |
Energy Storage System paired with Tesla Gateway for PCS functionality. May be paired with PV system. |
Tesla Inc. |
1462965-XX-Y [480V, 2hr] |
ESS |
Tesla Site Controller & Accuenergy Acuvim II Meter & compatible CTs |
Energy Storage System paired with Tesla Site Controller for PCS functionality, may be paired with PV system |
Tesla Inc. |
1462965-XX-Y [480V, 4hr] |
ESS |
Tesla Site Controller & Accuenergy Acuvim II Meter & compatible CTs |
Energy Storage System paired with Tesla Site Controller for PCS functionality, may be paired with PV system |