| Enphase Energy, Inc. |
ENCHARGE-3T-1P-NA |
ESS |
For Import Only Mode: Enphase IQ Combiner or Envoy, Enphase CT-200-SPLIT, Enphase Enpower
For Export Only Mode: Enphase IQ Gateway, at least one CT-200-SPLIT or CT-200-CLAMP for ESS, at least two CT-200-SPLIT or CT-200-CLAMP for consumption, at least one CT-200-SOLID for PV, Enphase IQ System Controller 3/3G (optional), Enphase IQ System Controller 2 (optional) |
For Import Only Mode: Energy Storage System paired with Enphase IQ Combiner or Envoy for PCS functionality. May be paired with PV system, resulting in an increased maximum open loop response time of 9 seconds.
For Export Only Mode: Energy Storage System paired with Enphase IQ Gateway for PCS functionality. May be paired with PV system, and/or Enphase IQ System Controller. |
| Enphase Energy, Inc. |
ENCHARGE-3-1P-NA |
ESS |
Enphase IQ Combiner or Envoy, Enphase CT-200-SPLIT
Backup Enabled: Enphase Enpower |
Energy Storage System paired with Enphase IQ Combiner or Envoy for PCS functionality. May be paired with PV system, resulting in an increased maximum open loop response time of 9 seconds. |
| Enphase Energy, Inc. |
ENCHARGE-10T-1P-NA |
ESS |
For Import Only Mode: Enphase IQ Combiner or Envoy, Enphase CT-200-SPLIT, Enphase Enpower
For Export Only Mode: Enphase IQ Gateway, at least one CT-200-SPLIT or CT-200-CLAMP for ESS, at least two CT-200-SPLIT or CT-200-CLAMP for consumption, at least one CT-200-SOLID for PV, Enphase IQ System Controller 3/3G (optional), Enphase IQ System Controller 2 (optional) |
For Import Only Mode: Energy Storage System paired with Enphase IQ Combiner or Envoy for PCS functionality. May be paired with PV system, resulting in an increased maximum open loop response time of 9 seconds.
For Export Only Mode: Energy Storage System paired with Enphase IQ Gateway for PCS functionality. May be paired with PV system, and/or Enphase IQ System Controller. |
| Enphase Energy, Inc. |
ENCHARGE-10-1P-NA |
ESS |
Enphase IQ Combiner or Envoy, Enphase CT-200-SPLIT
Backup Enabled: Enphase Enpower |
Energy Storage System paired with Enphase IQ Combiner or Envoy for PCS functionality. May be paired with PV system, resulting in an increased maximum open loop response time of 9 seconds. |
| Energizer Solar |
Force 9.6DC |
Inverter |
UL 2808 certified External CTs |
Inverter with PCS functionality |
| Energizer Solar |
Force 7.6DC |
Inverter |
UL 2808 certified External CTs |
Inverter with PCS functionality |
| Energizer Solar |
Force 5.7DC |
Inverter |
UL 2808 certified External CTs |
Inverter with PCS functionality |
| Energizer Solar |
Force 3.8DC |
Inverter |
UL 2808 certified External CTs |
Inverter with PCS functionality |
| Energizer Solar |
Force 11.4DC |
Inverter |
UL 2808 certified External CTs |
Inverter with PCS functionality |
| ELM Fieldsight, LLC |
MG2-AC1-1500-12-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1500-11-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1500-10-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1500-09-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1500-08-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1500-07-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1500-06-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1500-06-A |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1500-05-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1500-05-A |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1000-12-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1000-11-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1000-10-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1000-09-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1000-08-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |
| ELM Fieldsight, LLC |
MG2-AC1-1000-07-B |
ESS |
ELM Microgrid (FSCW-S30 or FSCW-UNO) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs. |
ESS with Additional Devices |