Grid Support Solar/Battery Inverters

Download Excel file

Note #1: Grid support inverters are inverters that include advanced functionality and communication abilities and are commonly known as “smart inverters”. The Grid Support Inverter List includes information for solar and battery inverters. Note that inverters on the Grid Support Inverter List are capable of different levels of advanced functionality. It is important that you verify with the applicable utility, AHJ, or responsible entity whether a specific inverter contains the level of functionality required by their “smart inverter” definition. Information about advanced inverter functionalities can be viewed by exporting the list.
Note #2: Hybrid inverters are capable of taking DC power input from both a solar system and an energy storage system. These models are listed on both the solar and battery inverter lists to reflect the dual functionality. Refer to the manufacturer's documentation for more information on the exact functionality and limitations.

Manufacturer ▲ Model Number Description Hybrid Inverter Maximum Continuous Output Power (kW) Nominal Voltage (Vac) Weighted Efficiency (%)
< 5 6 7 8 9 >
Altenergy Power System Inc. DS3-S [240V] 640 VA, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted N 0.656 240 96.5
Altenergy Power System Inc. DS3-L [240V] 768 VA, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted N 0.78 240 97
Altenergy Power System Inc. DS3 [240V] 880 VA, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted N 0.896 240 97
Altenergy Power System Inc. DS3-LV [120V] 900 VA, 120 Vac, Grid Support Utility Interactive Microinverter N 0.915 120 95
Altenergy Power System Inc. EZ1-LV [120V] 900 VA, 120 Vac, Grid Support Utility Interactive Microinverter N 0.915 120 95
Altenergy Power System Inc. DS3-H [240V] 1050 VA, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted N 1.068 240 97
Altenergy Power System Inc. QS1 [208V] 1.2 kW, 208 Vac Grid Support Utility Interactive Microinverter N 1.2183 208 96.5
Altenergy Power System Inc. QS1 [240V] 1.2 kW, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted N 1.225 240 96.5
Altenergy Power System Inc. QS1200 [240V] 1.2 kW, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted N 1.225 240 96.5
Altenergy Power System Inc. QS1A [240V] 1.5 kW, 240 Vac Grid Support Utility Interactive Microinverter N 1.516 240 96.5
Altenergy Power System Inc. QT2 [208V] 1728 VA, 208 Vac Grid Support Utility Interactive Inverter N 1.733 208 96
Altenergy Power System Inc. QT2-208 [208V] 1728 VA, 208 Vac Grid Support Utility Interactive Inverter N 1.733 208 96
Altenergy Power System Inc. QT2 [480V] 1800 VA, 480 Vac Grid Support Utility Interactive Inverter N 1.821 480 95.5
Altenergy Power System Inc. QT2-480 [480V] 1800 VA, 480 Vac Grid Support Utility Interactive Inverter N 1.821 480 95.5
Altenergy Power System Inc. ELS-3K [240V] 3.68 kVA, 240 Vac, Grid Support Utility Interactive Bi-directional Battery Inverter N 3.685 240 94
Altenergy Power System Inc. ELS-5K [240V] 5 kVA, 240 Vac, Grid Support Utility Interactive Bi-directional Battery Inverter N 5.008 240 94
Altenergy Power System Inc. ELS-7.6 [208V] ELS-7.6:7.6kVA,240 Vac Grid Support Utility Interactive Bi-directional Battery Inverter with PCS functionality. ELS-7.6:6.6kVA,208 Vac Grid Support Utility Interactive Bi-directional Battery Inverte N 6.606 208 93
Altenergy Power System Inc. ELS-7.6 [240V] ELS-7.6:7.6kVA,240 Vac Grid Support Utility Interactive Bi-directional Battery Inverter with PCS functionality. ELS-7.6:6.6kVA,208 Vac Grid Support Utility Interactive Bi-directional Battery Inverte N 7.609 240 94
Altenergy Power System Inc. ELS-9.6 [208V] ELS-9.6:9.6kVA,240 Vac Grid Support Utility Interactive Bi-directional Battery Inverter with PCS functionality. ELS-9.6:8.3kVA,208 Vac Grid Support Utility Interactive Bi-directional Battery Inverter N 8.308 208 93.5
Altenergy Power System Inc. ELS-9.6 [240V] ELS-9.6:9.6kVA,240 Vac Grid Support Utility Interactive Bi-directional Battery Inverter with PCS functionality. ELS-9.6:8.3kVA,208 Vac Grid Support Utility Interactive Bi-directional Battery Inverter N 9.606 240 94
Altenergy Power System Inc. ELS-11.4 [208V] ELS-11.4:11.4kVA,240 Vac Grid Support Utility Interactive Bi-directional Battery Inverter with PCS functionality. ELS-11.4:10kVA,208 Vac Grid Support Utility Interactive Bi-directional Battery Inverte N 10.011 208 93.5
Altenergy Power System Inc. ELS-11.4 [240V] ELS-11.4:11.4kVA,240 Vac Grid Support Utility Interactive Bi-directional Battery Inverter with PCS functionality. ELS-11.4:10kVA,208 Vac Grid Support Utility Interactive Bi-directional Battery Inverte N 11.415 240 94
Amensolar Ess Co., Ltd N3H-X5.0-US [240V] 5 kW, 240 Vac, Grid Support Utility Interactive Hybrid Inverter Y 5.09 240 97
Amensolar Ess Co., Ltd N3H-X5US [240V] 5.0 kW, 240Vac Grid Support Utility Interactive Hybrid Inverter Y 5.09 240 97
Amensolar Ess Co., Ltd N3H-X6.0-US [240V] 6 kW, 240 Vac, Grid Support Utility Interactive Hybrid Inverter Y 6.117 240 97